Thumbnail
Related to
Caule
F016N21K006.AGrey

Caule Floor 1 Nest

Outdoor floor lamp emitting direct or diffused light for outdoor use. Flexible stem structure in AISI 304 stainless steel with base in AISI 304 stainless steel. Lamp head available in two different models: solid moulded aluminium, for direct soft light, with sanded glass screen integrated or with a ‘nest’ cover, a metallic mesh in AISI 316L stainless steel featuring a methacrilate screen creating a unique wash of diffuse light. Integrated LED light source. Integrated 220–240V power supply. Supplied with 5 m outdoor cable with Schuko IP44 plug and IP65 backlit pedal dimmer for ON/OFF and light adjustment. 110V version and Casambi function available upon request.

4W - 124lm - 2700K - CRI> 80

Technical Drawing
DR_CAULE-FLOOR-1-NEST
Main specifications
EAN
8054793255309
Mounting
Floor
Light source type
LED
Light sources included
Yes
LED type
Power LED
Number of lamps
1
Power (W)
4
System power (W)
3.5
Lumen Output (lm)
124
Schematic light drawing
F016N21K0XX.A
Photometric
Lighting type
Direct
Light distribution
Symmetric
CCT (K)
2700
CRI>
80
Extreme cut off
No
Electrical
Insulation class
III
Frequency (Hz)
50/60
Main voltage (Vac)
220-240
Power supply
Integrated
Dimmable
Yes
Power supply type
Dimmer on board
Dimming interface
Dimmer Integrated
Emergency
No
Physical
Colour
Grey
Trim
No
Orientation
Fixed
Net weight (kg)
11.98
IP internal
65
Dynamic load (kg)
No
CE
RG
UL
ENEC
IECEC
65
IK04 - 0.50 Joule
Notes

We recommend using a connection system with a degree of protection greater than or equal to the degree of protection of the luminaire.
During the installation and the maintenance of the fixtures it is important to be careful and avoid damages on the paint coating.
Damages on the coating exposed to outdoor conditions or water, could cause corrosion.
Chemical substances affect the anticorrosion covering protection.
For LED fixtures, there is evidence that most of the damages are connected to electrical effects related to the insulations, which cause destructive electrical discharges
These effects are frequently caused by:
• over voltage coming from the mains’ network where fixture is connected.
• electrostatic discharge (ESD) coming from the environment.
The use of a protective device against the overvoltage on the electrical installation is warmly suggest this helps to reduce the intensity of some of these phenomenon and prevent irreversible damages. The selection of the type of device to be used must be adjust on the electrical plant.

Download

Tech spec pdf
Mounting instructions

Photometric Files

LDT / IES

Technical Drawings

2D
3D
Bim

Ecodesign and Energy Labelling

REPLACEABLE2

PWRSUPRPL2